In iRIXS Labview software interface, “Instrument” – “Setup Instrument Parameters”: Click the Cooler on/off” button to turn OFF the cooling of CCD and click “Function” - “SAVE”!. Start RIXS measurements (see Software interface below)!. For hrRIXS, you may start experiments directly with the " laser point". (as of 2020/07, Y +3 from the " laser point" will get decent S-L signals) For htRIXS, move Y-axis to optimize the peak intensity. Turn off lightening, cover all viewports, Open the valve to the spectrometer. Set the the spectrograph parameters – only need to set values shown in italic bold below, other values were not for users to change. As of 2020/07, two alignment lasers were setup to loacate the sample position without the need of X-ray beam. Update: Fe3O4 is replaced by Au (top) & CdS (below) films as of April 2016Ī Routine Procedure to Start RIXS experiments in iRXIS: See image: attach samples ONLY to the black area or on the round plate if used. Note: Sample holders are of 1 inch diameter, but leave about 2mm edge area for the grabber collets. Note: Do not over-tighten(close) the transfer arm collets Note: Do NOT take away the sample holder from beamline after your experiments!
This is done by rotating the center wheel between the two magnet groups of the transfer arm.
Open/close the transfer arm magnet groups will close/open the collets of the transfer arm to grab/release the sample holder. The sample holder is locked into the sample parks in loadlock and manipulator by matching the 3 notches on the sample holder with the 3 pressing keys of the sample park, press the holder in and rotate a small angle (about 10 degrees), the sample holder will be locked in place. IRIXS component locations and definitionsįigure 1: Corresponding motors shown in the iRIXS BCS main control Labview interface.Ĭheck out video demonstrations of sample transfer: 83400 cts for BL8.0.1B (qRIXS) branchline. H1 translation: 0 cts in BCS motor control 0.38 on scale. H1 tilt angle (axis-1): 8.49641 mm (do NOT touch unless you know what is this). Pull out V11 Translation= -10000 counts for rollup experiments!.
Do NOT go beyond 5.8mm on V11 benders!!.
#ANDOR SOLIS SOFTWARE MANUAL MANUAL#
HtRIXS manual controls and parameter settings IRIXS Software (check beamline software manual for XAS software) Parameters and examples for htRIXS (LE and HE settings) Sample transfer guideline ( Reference samples on manipulator)Ī Routine Procedure to Start RIXS experiments in iRXISĭetailed information & parameter settings If needed, see beamline software manual here
#ANDOR SOLIS SOFTWARE MANUAL PDF#
IRIXS technical details and references: iRIXS & htRIXS design: Qiao et al., Review of Scientific Instruments 88, 033106 (2017) doi: 10.1063/1.4977592 ( PDF) iRIXS hrRIXS design: Chuang et al., Review of Scientific Instruments 88, 013110 (2017) doi: 10.1063/1.4974356 ( PDF)Ī downloadable PDF of an old version, Rev 3.0, iRIXS manual is available here! The purpose of this manual is for providing a reference, a reminder, or a general guideline for users who know what they are doing. Reading this manual does NOT automatically authorize anyone to operate any synchrotron beamline. Anyone operating a synchrotron beamline should have some sort of OJT. 2020/07ĭISCLAIMER: A synchrotron beamline is NOT something one could operate by just reading through a manual. IRIXS User Manual (Wanli Yang office Server) BL8.0.1.1 iRIXS Operation Manual (Rev 4.0) -Suggestions? Please email Wanli Yang - Ver.